Proudly Australian Designed and made to Australian Standards The Galvanised Smart T-Bar™ is an Australian designed lightweight lintel used for supporting brickwork over openings. Typically used for double brick with no cavity, some common uses include garage door openings. It is a fully welded bar and is not reliant upon composite action. We also have other smart T-Bar™ sizes available. Please contact our sales department for more information.
  • Reliable shipping across QLD
  • Proudly Australian designed and made to Australian standards
  • Hot Dip Galvanised
  • In stock, ready to ship
  • Backordered, shipping soon
Size
Length
Regular price $774.87
/
Tax included. Shipping calculated at checkout.
  • Proudly Australian Designed and made to Australian Standards

The Galvanised Smart T-Bar™ is an Australian designed lightweight lintel used for supporting brickwork over openings. Typically used for double brick with no cavity, some common uses include garage door openings. It is a fully welded bar and is not reliant upon composite action.

We also have other smart T-Bar™ sizes available. Please contact our sales department for more information. 

  • Hot Dip Galvanised to AS/NZ 4680:2006
  • R3 Durability Rating in accordance with AS/NZS 2699:2002
  • Lightweight when compared to traditional Concrete/Brick Lintels
  • Available in a range of sizes.

Download Brochure

Lintel Load Tables: Download PDF

To find our more information on this product and other products visit the Brochures 

Section Properties

DIMENSIONS    SECTION PROPERTIES      
Designation  Mass per Metre  Gross Section Area About x-axis   About y-axis
Flange—Horizontal (H) mm    Ag Ix Zx  Iy
Web—Vertical (V) mm kg/m   mm^2 10^6 mm^4 10^3 mm^3 10^6 mm^4
200x6(H) +200x6(V) 18.84  2400  10.4  32  4.003
200x6(H) +200x8(V)   21.98  2800  12.6  72  4.009
200x6(H) +200x10(V) 25.12  3200  14.6  115  4.017
200x10(H) +200x10(V) 31.4  4000  17.7  127  6.69

Budabar T bars - Safe load tables

200x6 flange  Span (mm) 1800  2100   2400  2700  3000  3300
200x6 web  Bar Length(mm)  2100 2400 2700 300 3300 3600
18.84kg/m  UDL (kg/m)  1015 750   585  468  375  310
   Point Load(kg)  995  843  745  668  600  535

 

200x6 flange  Span (mm)  2400  2700  3000  3300  3600 3900 
200x8 web  Bar Length(mm)  2700  3000 3300 3600 3900 4200
21.98kg/m  UDL (kg/m)  1350  1065  870  725  605  515
   Point Load(kg)  1715  1525  1375  1255  1135  1050

 

200x6 flange  Span (mm)  3600  3900  4200  4500  4800  5100 5400  5700
200x10 web  Bar Length(mm)  3900  4200  4500  4800  5100  5400 5700

 6000

25.12kg/m  UDL (kg/m)  825  650  515  410  345  280  230  195
   Point Load(kg)  1825  1635  1415  1210  1065  915  805  715

 

200x10 flange  Span (mm) 3600 3900 4200 4500  4800 5100   5400
200x10 web  Bar Length(mm)  3900  4200  4500  4800  510  5400  5700
31.4kg/m  UDL (kg/m)  980  828  703  580  480  385  320
   Point Load(kg)  2015  1865  1685  1475  1280  1125  1075

 

200x10 flange  Span (mm)  5700  6000  6300  6600  6900  7200
200x10 web  Bar Length(mm)  6000  6300  6600  6900  7200  7500
31.4kg/m  UDL (kg/m)  265  228  190  165  140  116
   Point Load(kg)  990  865  775  685  620  550

 

Notes on Safe Load Tables for Budabar-T-Bars

The Buda-T-Bar is imported from China, material used is Q235B, Q235 material is in accordance with PRC standard GB 700(previous version GB700-79 part A3 & C3), and here Q stands for yielding. According to PRC
National Standard GB700-88, the minimum yielding point is 235Mpa for thicknesses less than 17mm, tensile strength is between 375-400MPa, E=200~210 GPa

  • The Buda-T-Bar is simply supported at both ends.
  • The Buda-T-Bar is loaded such that the load acts vertically and equally on both sides of the web.
  • The Buda-T-Bar is considered as being laterally unrestrained for the full span length.
  • UDL loads are constant along the length of the bar.
  • Point loads act at mid-span.
  • 150mm minimum bearing support on to brickwork.
  • Hot-dip galvanising to AS / NZS 4680:2006.
  • Loads are in accordance with AS / NZS 1170.1:2002.

Note:

  1. a minimum of three courses of bricks must be laid above the lintel beam.
  2. Load limited by deflection of 1/500 span.
  3. Yielding stress fy=235 Mpa, tensile strength fu=375Mpa for both web and flange.
  4. Mass per metre calculation is based on 7850kg/m^3.
  5. Calculate bar length is span+150mm each end.

Tab 4 supports multi-line text.

But not hyperlinks and formatting.

Tab 4 supports multi-line text.

But not hyperlinks and formatting.

Our inventory: 99% of our stock is consistently available. If an item is unavailable, it will either be marked as out of stock online or we will promptly notify you.

Shipping costs: To determine delivery costs, please input your suburb and postal code on the shopping cart page.

Our goal is to deliver orders placed before 12pm within Brisbane Metro the following business day via a Ute or Crane Truck.

Orders outside of Brisbane metro can expect delivery 1 to 2 days later. Currently, we only deliver this product to Brisbane, Sunshine Coast to Gympie Region, and Gold Coast down to selected areas in Northern NSW.

Input your postal code in the shopping cart to check if we deliver to your location.

We do provide free pick up if you prefer to collect the items yourself or arrange your own transportation.

Please be aware that truck deliveries with a crane can only lift materials off the truck and into the boundary of your front or back yard. We cannot guarantee a specific location or lift the material above the ground floor (first floor or higher) due to various factors.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Recently viewed